Anchorage
Anchor pointsWebbing/D-RingPass
Anchor accessories17/400mmPass
Structure
Seam securityOKPass
Stitching3-8mmPass
Blower tube1.2m+Pass
Walls and towersOKPass
Step / ramp sizeN/A
GroundingPass
Sharp anglesPass
PressureOver 1kPa MinimumPass
Fall-off height0.58m Bed HeightPass
Trough depth170/600mmPass
EntrapmentOKPass
StabilityOKPass
Deflation / evacuationOKPass
Air lossPass
MarkingsLABELPass
IdentificationLABELPass
Materials
Fabric flame retardancyEN14960 MATERIALSPass
Fabric strengthEN14960 MATERIALSPass
ZipsCOVEREDPass
ThreadEN14960 MATERIALSN/A
RopesN/A
NettingN/A
WindowsN/A
ArtworkOK Pass
Totally enclosed details
ExitsN/A
Exit markingsN/A
Independent supportN/A
Emergency lightingN/A
Deflation of user areaN/A
Slides
Height of walls1.25m or Contained by roofPass
Run-out+50% of PlatformPass
Clamber netStepsPass
Slide sheetVelcro OKPass
Additional details
Anchor typeWEBBING/D-RINGPass
Number of anchors12Pass
Open-side fall-off height0.58m Pass
Inside wall heightPass
Play areaPass
Max users by height
Up to 1.0 m6
Up to 1.2 m6
Up to 1.5 m6
Up to 1.8 m6
Risk assessment notes
None recorded
Inspection. This inspection certifies that the equipment described above conforms to BS EN 14960. Where an item falls outside the scope of the standard, it has been manufactured and tested to that standard as closely as the design allows.
PASSED